trusted seller
Uv Visible Spectrophotometer Uv Visible Spectrophotometer

Uv Visible Spectrophotometer

100 INR/Piece

Product Details:

  • Application Mass Transfer Lab Equipments
  • Product Type Uv Visible Spectrophotometer
  • Usage Mass Transfer Lab Equipments
  • Click to view more
X

Uv Visible Spectrophotometer Price And Quantity

  • 100 INR/Piece
  • 1 Piece

Uv Visible Spectrophotometer Product Specifications

  • Mass Transfer Lab Equipments
  • Mass Transfer Lab Equipments
  • Uv Visible Spectrophotometer

Uv Visible Spectrophotometer Trade Information

  • Yes
  • Sample costs shipping and taxes has to be paid by the buyer
  • carton box, export quality also available
  • All India
  • ISO 9001, 14001 ,CE

Product Description

Uv Visible Spectrophotometer

  • Photometric system:Double-beam optics
  • Photometric system:Czerny-Turner mounting
  • Double monochromatic
  • Lo-Ray-Light grade blazed holographic grating
  • Detector:R-928 Photomultiplier
  • Light source:50 W halogen lamp, deuterium lamp, light source auto position adjustment built in
  • Setting wavelength range:185"1400 nm
  • Measurement wavelength rang:185"900 nm .The ISR-2600Plus Integrating Sphere Attachment used.
  • Wavelength accuracy 0.1 nm (656.1 nm D2), ï 0.3 nm (all range)
  • Wavelength repeatability 0.05 nm
  • Wavelength scanning speed:Wavelength slew rate:about 14000 nm/min
  • Wavelength setting:Wavelength scan rate: about 4000 to 0.5 nm/min
  • Lamp interchange wavelength:At 1 nm units for scan start and scan end wavelengths, and 0.1
  • nm units for other wavelengths
  • Spectral bandwidth:Auto switching synchronized with wavelength; switching range
  • Selectable between 290 and 370 nm (0.1 nm units)
  • Resolution:0.1 nm
  • Stray light:Max. 0.00005 % (220 nm, NaI)
  • Max. 0.00002 % (340, 370 nm, NaNO2)Max. 1 % (198 nm, KCl)
  • Photometric modes:Absorbance (Abs.), transmittance (%), reflectance (%), energy (E)
  • Photometric range:Absorbance: 8.5 to 8.5 Abs
  • Transmittance, reflectance:0 to 100000 %
  • Photometric accuracy: ï 0.002 Abs (0.5 Abs)
  • ï 0.003 Abs (1 Abs)
  • ï 0.006 Abs (2 Abs)
  • ï 0.3 %T
  • Measured using NIST930D/NIST1930 or equivalent filter
  • Photometric repeatability 0.001 Abs (0.5 Abs)
  • ï 0.001 Abs (1 Abs)
  • ï 0.003 Abs (2 Abs)
  • ï 0.1 %T
  • Noise level:0.00005 Abs RMS (500 nm)
  • Baseline flatness 0.0004 Abs (200 x 860 nm), 1 hour after light source is turned ON
  • Baseline stability:Within 0.0003 Abs/h (700 nm), 1 hour after light source is turned ON
  • Sample compartment:Internal dimensions:W150 x D260 x H140 (mm)
  • Distance between light beams:100 mm
  • Maximum optical path length of cell:100 mm
  • Dimensions:W450 x D600 x H250 (mm)
  • Weight:23 kg
  • Operating temperature:15C to 35C
  • Operating humidity:30 % to 80 % (no condensation, less than 70 % above 30 C)
  • Power requirements:100 to 240 VAC, 50/60 Hz
  • Power consumption:170 VA Including PC and printer

Features:

  • Select the items to implement during inspection to confirm the approximate time required for full inspection.
  • The system is capable of both wavelength repeatability checks and wavelength accuracy checks using a wavelength calibration filter. If the optional mercury lamp unit is used, wavelength accuracy can be inspected using the low-pressure mercury lamp's bright line.
  • The software is capable of resolution inspections using methods defined in the EP (European Pharmacopoeia) and USP (United States Pharmacopoeia) as well as the method for checking the bright line spectral bandwidth.

Enter Buying Requirement Details
Email Id
Mobile number

Other Products in 'Mass Transfer Lab Equipments' category



Back to top