Planter Test Apparatus

Planter Test Apparatus

10 INR/Piece

Product Details:

  • Product Type Planter Test Apparatus
  • Application Civil Engineering Lab Equipments
  • Usage Civil Engineering Lab Equipments
  • Click to view more
X

Planter Test Apparatus Price And Quantity

  • 1 Piece
  • 10 INR/Piece

Planter Test Apparatus Product Specifications

  • Planter Test Apparatus
  • Civil Engineering Lab Equipments
  • Civil Engineering Lab Equipments

Planter Test Apparatus Trade Information

  • 100 Piece Per Week
  • 1 Week
  • Yes
  • Sample costs shipping and taxes has to be paid by the buyer
  • carton box, export quality also available
  • Asia Middle East Africa
  • All India
  • ISO 9001, 14001 ,CE

Product Description

Planter Test Apparatus

The Plantar Test Analgesia Meter for paw stimulation can be used on 12 mice, 6 rats and other animals (cats, rabbits) unrestrained when testing for narcotic drugs. Experiments are easy to perform, simply slide the test head under test subject, align the heat source via our exclusive guide light (idle state) by the attached, adjustable, angled mirror on test head to test subject and perform tests.

Start, stop and reset of tests is done by either the push button on test head, front panel controls or supplied foot switch.

With our exclusive idle state of the heat source one is assured of exact placement of the heat source. Tests are performed on the plantar surface by a focused, radiant heat light source. The light beam is focused to the top of the glass and creates a 4X6mm intense spot on the paw.

Our method of visible light is superior to the infrared light method, since a user will not always know exactly where/when the test will start, causing false starts and conditioning of animals. A built-in timer displays reaction time in .01 second increments.

The height of the glass is adjustable allowing the focal point of the light to be adjusted to stimulate other body parts if needed. A Humane cutoff timer is standard. The unit can be preset for a cutoff period, at the end of which the heat source shuts off automatically if the animal has not responded, avoiding tissue damage. Our test head does not emit , clicking or whining noises that cause preconditioning of animals prior to test as with other systems on the market.

Our exclusive heated glass option eliminates the glass acting as a heat sink. This feature will eliminate the reaction time of the animals to be altered due to the fact that they are placed on cold glass allowing the possibility of delayed response time to the applied heat source. Built-in heating elements in the glass which are digitally controlled for consistent temperatures. Temperature readout and adjustment from 30-40 degrees c. for the heated base is controlled on the heated base.

TAIL TEMPERATURE OPTION (T)
Measurement of tail temperature at all times.

Trigger temperature is automatic at the start of every test.

This optional feature allows automatic preheating of the tail. To ensure experiment protocols to be precisely controlled and repeated. This feature allows the user to SET the tail temperature at start of each test is to be started at up to 75 degrees Celsius. Once that preset temperature is reached the test and the timer starts automatically and after the tail flicks the timer and light stop and the result is displayed. Readout will now show in repeatable sequence the start and end temperatures as well as test time.

Features

  • Tail Temperature optional (T)
  • Precise Programmable digital control
  • Humane cut-off feature, set by user
  • Adjustable beam intensity in 1% increments
  • Reaction is detected automatically
  • (Tail Flick Test set-up)
  • Manual override of all timer functions
  • All Functions and parameters entered via key-pad
  • Heated glass option only from IITC
  • Foot switch - RS232 - Printer output (standard)
  • Software - USB - (optional)