trusted seller
Gas Absorption Column

Gas Absorption Column

10 INR/Piece

Product Details:

  • Usage Chemical Engineering Laboratory Equipments
  • Product Type Gas Absorption Column
  • Application Chemical Engineering Laboratory Equipments
  • Click to view more
X

Gas Absorption Column Price And Quantity

  • 1 Piece
  • 10 INR/Piece

Gas Absorption Column Product Specifications

  • Chemical Engineering Laboratory Equipments
  • Chemical Engineering Laboratory Equipments
  • Gas Absorption Column

Gas Absorption Column Trade Information

  • Cash Advance (CA) Telegraphic Transfer (T/T) Letter of Credit (L/C) Cash in Advance (CID) Cheque
  • 100 Piece Per Week
  • 1 Week
  • Yes
  • Sample costs shipping and taxes has to be paid by the buyer
  • carton box, export quality also available
  • All India
  • ISO 9001, 14001 ,CE

Product Description

Gas Absorption Column : MTS-909

This apparatus is used to determine the air pressure differential across the column as a function of air flow rate at different water flow rates down the column, and flooding point can be noted. Absorption process of carbon dioxide from air-CO2 mixture into caustic soda solution, is also studied using this system.

The system components are mounted within a floor standing painted steel framework.
The wetted wall column is a glass column with water inlet and outlet sections and is gimbal mounted to ensure that it can be set accurately vertical.
The deoxygenating column is of similar overall size to the wetted wall column, standing vertically adjacent to it. Beside the columns is a control console housing flow meters, pump controls and oxygen analyser. Situated between the columns are two special housings containing the oxygen analysis probes which monitor the oxygen content in the water entering and leaving the absorption column. The apparatus uses water as the working medium, contained in a storage tank at the rear of the unit. Pumps delivering water to the deoxygenator and the absorption column are located at the base of the unit.
Dissolved oxygen at inlet and outlet can be measured in rapid succession. The water drains into the storage tank to be recycled to the deoxygenator.
 
In operation, water is sparged with nitrogen in the deoxygenator before entering the top of the wetted wall column. Air is pumped by the integral diaphragm type air pump into the base of the column. The air passes up the column, giving up the oxygen to the water.
 

Enter Buying Requirement Details
Email Id
Mobile number

Other Products in 'Chemical Engineering Laboratory Equipments' category



Back to top