trusted seller
MEASUREMENT OF LEVEL BY CAPACITANCE METHOD APPARATUS MEASUREMENT OF LEVEL BY CAPACITANCE METHOD APPARATUS MEASUREMENT OF LEVEL BY CAPACITANCE METHOD APPARATUS

MEASUREMENT OF LEVEL BY CAPACITANCE METHOD APPARATUS

100 INR/Piece

Product Details:

  • Product Type MEASUREMENT OF LEVEL BY CAPACITANCE METHOD APPARATUS
  • Application MEASUREMENT OF LEVEL BY CAPACITANCE METHOD APPARATUS
  • Usage MEASUREMENT OF LEVEL BY CAPACITANCE METHOD APPARATUS
  • Click to view more
X

MEASUREMENT OF LEVEL BY CAPACITANCE METHOD APPARATUS Price And Quantity

  • 100 INR/Piece
  • 1 Piece

MEASUREMENT OF LEVEL BY CAPACITANCE METHOD APPARATUS Product Specifications

  • MEASUREMENT OF LEVEL BY CAPACITANCE METHOD APPARATUS
  • MEASUREMENT OF LEVEL BY CAPACITANCE METHOD APPARATUS
  • MEASUREMENT OF LEVEL BY CAPACITANCE METHOD APPARATUS

MEASUREMENT OF LEVEL BY CAPACITANCE METHOD APPARATUS Trade Information

  • Cash Advance (CA) Cash in Advance (CID) Cheque Letter of Credit at Sight (Sight L/C) Telegraphic Transfer (T/T) Letter of Credit (L/C)
  • carton box, export quality also available
  • Asia Middle East Africa
  • All India
  • ISO 9001, 14001 ,CE

Product Description

The present set-up is designed tostudy the working principle and calibration procedure of capacitance type leveltransmitter.

The set-up consists of a probewhich is mounted in a level tank with graduated scale.

Water is poured in the level tankmanually and response of the level transmitter is indicated on the LevelIndicator.

Output of the transmitter can bemeasured using Digital Current meter.

A drain valve is provided at thebottom of the level tank which enables the student to observe and measure theresponse of capacitance type level transmitter at different liquid heights.

The set-up is complete with Leveltank, level transmitter, current indicator and necessary piping.

All component and accessories areproperly mounted on the rigid MS structure and fitted on a base plate to form atable top set-up.

Experimentation/learning objectives:

To study of working principle andcalibration procedure of capacitance type level transmitter.

To study of linearity, accuracyand repeatability of capacitance type level transmitter.

Utilities required:

Electric supply: Single Phase,220 V AC, 5-15 amp combined socket with earth connection.

Earth voltage should be less than5 volts.

Water supply: Initial fill

Floor Drain.

Floor area: 1.0 m x 0.5 m

Technical details:

Level Transmitter: Capacitancetype, Input 0-300 mm of water. Output 4-20 mA DC

Digital Current Meter: DigitalIndication of Current output. Range 0-30 mA DC

Level Tank: Acrylic/Glass, PVC

Piping: Size ¼